Cloud HMI, Built-in EasyAccess 2.0

CMT-SVR-102

อัตราค่าจัดส่ง

รายละเอียดสินค้า

Cloud HMI, ARM Cortex A8 600MHz, 1024x748, 256MB RAM, 256MB Flash, real time clock, Com1: RS-232, Com2: RS-485 2w/4w, Com3: RS-485 2w, EasyAccess 2.0

 Memory  
 Storage (MB)  
256
 RAM (MB)  
256
 Processor  
 
ARM Cortex A8 600 MHz
 I/O Port  
 SD Card Slot  
SD/SDHC
 USB Host  
USB 2.0 x 1
 USB Client  
 
 Ethernet  
10/100/1G x 2
 COM Port  
COM1 RS-232, COM2 RS-485 2W/4W, COM3RS-485 2W 
CAN Bus
N/A
HDMI
N/A
RTC
 
Built-in (CR 1225 3V lithium battery)
 Power  
 Input Power  
24±20% VDC
 Power Consumption  
230mA@24V
Power Isolation
Built-in
Voltage Resistance
500 VAC (1 min)
Isolation Resistance
Exceed 50 MΩ at 500 VDC
Vibration Endurance
10 to 25 Hz (X, Y, Z directions 2 G 30 mins)
Specification
Enclosure
Plastic
Dimension (inch)  
5.12 x 4.53 x 1.06
Weight (lb)  
0.4
Mount
35 mm Din rail mounting
Storage Temperature
 -4°F~158°F
Operating Temperature
 -4°F~131°F
Relative Humidity
10%~90% RH (non-condensing)
Software
 

Server/Client HMI architecture

This Weintek cMT series from Weintek offfers a number of solutions:

Solution 1:

Smart communication gateway with data processing functions of an HMI which can quickly help you build IIot solutions.

Get notified on a mobile phone, EasyAccess 2.0 can remotely debug or update devcies or remote monitoring of HMI's with cMT Viewer APP.

The HMI is not just for operating machines or collecting and managing data. It is a key player in IIoT as a Communication Gateway. The data in the device connected to HMI can be published to IIoT system.

Solution 2:

You can control the HMI and execute the third party apps at the same time!

With EasyLauncher you can easily access third party apps including MS Office, PDF Reader, Media player and many more. Used with cMT VIewer you can monitor and control the HMI at the same time.

Solution 3:

You can have more flexible installations to operate your HMI!

You can install your cMT-SVR, which is dedicated to data processing and communication protocol conversion, and PLC in the same control cabinet. You can also install one or more cMT-iV5s located on any place of the machine for connecting to the same cMT-SVR.

Solution 4:

HMI is also an HMI server!

cMT3090/cMT3151 has a dual-core CPU greatly increasing data/graphic processing. You can use cMT Viewer to connect for monitoring and controlling.

cMT Viewer is running on cMT-iPC10/cMT-iPC15 or cMT-iV5.

The CMT series is a mobile solution with cMT Viewer and a remote solution with EasyAccess 2.0. 