Ultra-thin area sensor NA 2-N

NA2-N28-PN

Area Sensor
อัตราค่าจัดส่ง

รายละเอียดสินค้า

Area sensor – Panasonic (NA-2N / 28 beam channels) – Supply voltage (DC) 12-24V – (Sensing height) 540mm – Sensing range 5m / 5000mm – Beam pitch (Between beams) 20mm – Material ABS (Heat resistant) (Case)

Spec Detail

ItemSpecifications
Product NumberNA2-N28-PN
Part NumberNA2-N28-PN
CE marking directive complianceEMC Directive, RoHS Directive
Sensing height540 mm 21.260 in
Sensing range5 m 16.404 ft
Beam pitch20 mm 0.787 in
Sensing objectdia. 30 mm dia. 1.181 in or more opaque object (completely beam interrupted objects)
Supply voltage12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Power consumption:Emitter:Job indicator ON1.2 W or less
Power consumption:Emitter:Job indicator OFF1.1 W or less
Power consumption:Receiver:Job indicator ON1.2 W or less
Power consumption:Receiver:Job indicator OFF1.1 W or less
OutputPNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Output:Utilization categoryDC-12 or DC-13
Output:Output operationON when all beam channels are received (OFF when one or more beam channels are interrupted)
Output:Short-circuit protectionIncorporated
Response time10 ms or less (12 ms or less when the interference prevention function is used)
Indicators:EmitterEmitting indicator: Green LED x 2 (light up during emission; one LED lights up for Frequency A setting, both LEDs light up for Frequency B setting)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
Indicators:ReceiverOperation indicator: Red LED (lights up when one or more beam channels are interrupted)
Stable incident beam indicator: Green LED (lights up when all beam channels are stably received)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
* When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to operation of the short-circuit protection circuit.
Interference prevention functionIncorporated
Test input (emission halt) functionIncorporated
Pollution degree3 (Industrial environment)
ProtectionIP40(IEC)
Ambient temperature-10 to +55 degrees +14 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -10 to +60 degrees +14 to +140 degrees Fahrenheit
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 lx or less at the light-receiving face
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Emitting elementInfrared LED (Peak emission wavelength: 870 nm 0.034 mil, modulated) (Note:Peak emission wavelength has been changed from production in March, 2017.)
MaterialEnclosure: Heat-resistant ABS
Lens cover: Polyester
Indicator cover: Acrylic
Cable0.2 mm2 4-core cabtyre cable, 3 m 9.843 ft long
Cable extensionExtension up to total 25 m 82.021 ft is possible for both emitter and receiver, with 0.2 mm2, or more, cable.
Weight(Total weight of emitter and receiver)Net weight: 650 g approx.